Auto Advanced Ignition System Training Equipment

Auto Advanced Ignition System Training Equipment
Product Detailed
Related Categories:Valve Train
1. Auto Advanced Ignition System Educational Model 2. Ignition system for auto training

1. Auto Advanced Ignition System Educational Model

2. Ignition system for auto training  

About the product

The device holistically demonstrates the structure and operation of the engine ignition system based on real components of three ignition systems, including the contact-controlled ignition system, Hall electronic ignition system, Non-distributor grouping ignition system. The device applies to theoretical teaching and maintenance training of the ignition system in secondary and senior vocational skill schools, normal education and training institutions.

 

ii. Features

Three real and operable ignition systems are used to illustrate the structure and operating process of the ignition system. Such systems include the contact-controlled ignition system, Hall electronic ignition system, distributorless MPI ignition system. Color circuit and operating principle diagrams on the instruction board are fixed with aluminum rims. The diagrams and ignition systems can help trainees learn and analyze the operating principle of the systems. The instruction board is installed with detection terminals to detect electric signals, for example, resistance, voltage, current, and frequency, of circuit components of the ignition system. The teaching board's base frame is made of steel and the surface is paint-coated. Self-retention wheels are installed. Instead of using accumulators and requiring charging, the instruction board connects to a 220V AC voltage which changes to a 12V DC voltage through the internal circuit. The 12V DC voltage protects the instruction board against short circuit. Intelligent fault-setting and appraisal system:

1)      The system employs patented, stable and anti-virus digital integrated circuit board and the latest MCU technology and associated fault setting control technology.

2)      Independent test and appraisal can be performed without a computer. The teacher and student interfaces are separated. Teachers enter the teacher interface to provide test paper and the students answer questions on the ordinary interface. Teachers prepare the test: teachers prepare the test: Select "Setting fault point and fault type" through the main functional menu in the MML interactive interface. Enter the password to page for setting faults. Select the set faults from the fault name list. You can select three fault types including "Open circuit fault", "Short circuit fault", and "Improper contact". Students answer questions: Enter the main menu and select "Test for skills of finding faults". After finding the fault through a test operation, students select the fault name or type. If the answer is correct, the system displays that "Correct, the fault is removed"; If the answer is incorrect, the system indicates that "incorrect, please check again". The number of attempts for each question can be set to 1-10 by the teacher. Test bank applicable to the device is integrated. The test bank can be edited according to the requirements of users.

3)      High resolution 3.8-inch 0.225 x 0.225 LED monitor, Chinese menu interface, friendly MML. 4 operation keys make the operation simple and quick.

4)      Set the line breaking, grounding short circuit and improper contact faults at any circuit. Set and control common faults relevant to module pins. Users can adjust the number and type of fault setting points.

5)      The RJ45 network interface is installed and the RS-232 port is provided. Use the fault setting devices of network cable or other devices to form a network to control functions including fault setting, fault removal, parameter setting, remote startup, information feedback, and appraisal through the main control computer.

 

iii. Technical parameter

Size: 2400mm × 700mm × 1900mm (length x width x height) External power supply: A.C. 220V ± 10% 50Hz Operating voltage: 12V DC Operating temperature: –40ºC to +50ºC

 

iv. Basic configuration (unit)

No.

Name

Specification and model

Unit

Quantity

1

Detection control panel

With various detection terminals, color circuit and operating principle diagrams

Set

1

2

Contact-controlled ignition system

The ignition system of Changan, including an ignition switch, an ignition circuit, a distributor, and a spark plug

Set

1

3

Hall electronic ignition system

The ignition system of Volkswagen Jetta, including an ignition switch, an ignition circuit, igniter, a distributor, a spark plug, and a Hall sensor

Set

1

4

Non-distributor grouping ignition system

The ignition system of Toyota 5S-FE, including an engineer control unit (ECU), an ignition switch, a crankshaft position sensor, an igniter assembly, and a spark plug

Set

1

5

Manual driving mechanism

Set

2

6

Crankshaft position sensor and signal wheel

Set

2

7

Fuse box

Unit

1

8

Intelligent fault-setting and appraisal system

Set

1

9

Movable framework (with self-retention wheels)

2400mm × 700mm × 1900mm (length x width x height)

Set

1

 

Auto Advanced Ignition System Training Equipment